foxBMS
1.6.0
The foxBMS Battery Management System API Documentation
|
Header file of some software. More...
Go to the source code of this file.
Data Structures | |
struct | ADI_COMMAND_READ_REGISTERS_s |
Functions | |
uint16_t | ADI_GetStoredVoltageIndex (uint16_t registerVoltageIndex) |
Converts index of read voltages. More... | |
void | ADI_GetVoltages (ADI_STATE_s *adiState, ADI_VOLTAGE_REGISTER_TYPE_e registerType, ADI_VOLTAGE_STORE_LOCATION_e storeLocation) |
Reads and stores cell voltages. More... | |
void | ADI_StopContinuousCellVoltageMeasurements (ADI_STATE_s *adiState) |
Stop cell voltage measurement. More... | |
void | ADI_RestartContinuousCellVoltageMeasurements (ADI_STATE_s *adiState) |
Restart cell voltage measurement. More... | |
Header file of some software.
SPDX-License-Identifier: BSD-3-Clause
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
We kindly request you to use one or more of the following phrases to refer to foxBMS in your hardware, software, documentation or advertising materials:
Definition in file adi_ades183x_voltages.h.
uint16_t ADI_GetStoredVoltageIndex | ( | uint16_t | registerVoltageIndex | ) |
Converts index of read voltages.
This function translates the indexes of read voltages so that if some inputs are unused, they do not appear in the final cell voltage table
registerVoltageIndex | index of the read voltage ion the ades183x register |
Definition at line 391 of file adi_ades183x_voltages.c.
void ADI_GetVoltages | ( | ADI_STATE_s * | adiState, |
ADI_VOLTAGE_REGISTER_TYPE_e | registerType, | ||
ADI_VOLTAGE_STORE_LOCATION_e | storeLocation | ||
) |
Reads and stores cell voltages.
This function, reads the raw values from the registers, and calls ADI_SaveRxToCellVoltageBuffer() which convert them into voltages and stores them.
adiState | state of the ADI driver |
registerType | type of voltage register to read |
storeLocation | location where read data has to be stored |
Definition at line 352 of file adi_ades183x_voltages.c.
void ADI_RestartContinuousCellVoltageMeasurements | ( | ADI_STATE_s * | adiState | ) |
Restart cell voltage measurement.
This function should be called after deactivation of balancing
adiState | state of the driver |
SM_VCELL_RED: Cell Voltage Measurement Redundancy Set RD bit to enable redundant cell voltage measurements
Definition at line 403 of file adi_ades183x_voltages.c.
void ADI_StopContinuousCellVoltageMeasurements | ( | ADI_STATE_s * | adiState | ) |
Stop cell voltage measurement.
This function should be called before activation of balancing
adiState | state of the driver |
Definition at line 421 of file adi_ades183x_voltages.c.